JDS Uniphase RM3750 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola JDS Uniphase RM3750. JDS Uniphase RM3750 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - BACKREFLECTION METER

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 1 of 39RM3 SERIESBACKREFLECTION METERUser’s Manual

Strona 2 - Contents

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 10 of 39non-conductive pollution occurs. Occasionally, however, a temporary conducti

Strona 3 - 10112341 Rev 002 Page 3 of 39

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 11 of 39 General Information and SpecificationsGeneral Information This user’s manu

Strona 4 - Safety Information

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 12 of 39Backreflection MeasurementsReflections in optical systems can come from a n

Strona 5

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 13 of 39Output PortThe output port of the RM meter is equipped with an ultra-low ba

Strona 6 - Safety Instructions

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 14 of 39• User-calibration mode• RS232 serial and IEEE 488 GPIB parallel interface

Strona 7 - 10112341 Rev 002 Page 7 of 39

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 15 of 39Specifications The following optical specifications describe the warranted

Strona 8 - Safety Symbols

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 16 of 39* Flexcor is a trademark of CorningR.

Strona 9 - Compliance

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 17 of 39Table 4: Other Specifications Electrical Input voltage 100 to 240 V AC, 50

Strona 10 - USER’S MANUAL

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 18 of 39 Getting Started The RM3 Series Backreflection Meter consists of the meter

Strona 11 - General Information

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 19 of 39 Operating Environment In order for the unit to meet the warranted specific

Strona 12 - Loss and Power Measurements

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 2 of 39ContentsSafety Information, Instructions, and Symbols...

Strona 13

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 20 of 39invoice number, and an itemized statement of claimed defects must be includ

Strona 14 - Optional Accessories

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL 10112341 Rev 002 Page 21 of 391. Blow the sleeve with filtered compressed air (Figure 2).Figure 2: Conne

Strona 15 - Specifications

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 22 of 39Operating and Maintenance InstructionsFront PanelThe front of the meter (mod

Strona 16

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 23 of 39Rear PanelThe back of the meter (Figure 4) can vary with the model.-25 VA ma

Strona 17

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 24 of 39need to be made just before the high-attenuation bends in order to offset th

Strona 18 - Getting Started

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 25 of 39Figure 5b: Terminating the Jumper for BR Measurement for Single-mode (980 nm

Strona 19 - Storing and Shipping

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 26 of 396. Terminate the measurement jumper just before the output connector, and ho

Strona 20 - Cleaning Connectors

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 27 of 39temperature. To ensure accurate backreflection measurements below -65 dB (-2

Strona 21 - Powering Up the Meter

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 28 of 39 5. Attach the appropriate detector adapter to the detector on the front of

Strona 22 - Front Panel

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 29 of 394. Connect the output connector of the DUT to the detector on the front of

Strona 23 - Termination Techniques

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 3 of 39Front Panel...

Strona 24

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 30 of 39 Figure 9: Measuring Relative PowerPower AccuracyThe absolute accuracy of po

Strona 25

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 31 of 39Display Descriptionthe model number (XXXX) and the software version (Y.Y).ST

Strona 26 - Measuring Backreflection

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 32 of 39Backreflection Calibration AdjustmentThe RM meter has a factory-set backrefl

Strona 27

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 33 of 393. Press the λ key to select the wavelength at which the calibration check i

Strona 28 - Measuring Power

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 34 of 39Figure 10: Removing the Connector Panel2. Remove the connector from the mat

Strona 29

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 35 of 39 Loss Before the DUTWhen a DUT is connected to the RM meter, the loss from

Strona 30 - Messages and Symbols

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 36 of 39 Laser StabilityIf the messages “Source Unstable” or “Input Low” are displa

Strona 31 - Calibrating the Meter

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 37 of 39Programming GuideRS232 Serial InterfaceThe RM meter is equipped with an RS23

Strona 32 - Power Calibration Adjustment

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 38 of 39On power-up, the RTS and DTR signals on the interface connector go positive,

Strona 33 - Maintaining the Meter

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 39 of 39RS232-GPIB ConverterAn optional user-supplied RS232-to-IEEE 488 converter ca

Strona 34 - Troubleshooting

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 4 of 39Website: http://www.jdsuniphase.comSafety Information, Instructions, and Symb

Strona 35

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 40 of 39Programming ExamplesRS232 Interface Program ExampleThe following program can

Strona 36

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 41 of 39Customized Features and Test Data

Strona 37 - Programming Guide

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 5 of 39Under the laser classification of the US Food and Drug Administration (FDA) C

Strona 38 - Table 9: Character Commands

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 6 of 39 Safety Instructions The following safety instructions must be observed when

Strona 39 - RS232-GPIB Converter

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 7 of 39not use repaired fuses, and avoid any situations that can short-circuit thefu

Strona 40 - Programming Examples

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 8 of 39 Safety Symbols The following symbols and messages can be marked on the unit

Strona 41

RM3 SERIES BACKREFLECTION METERUSER’S MANUAL10112341 Rev 002 Page 9 of 39ComplianceCE Compliance The unit has been designed and tested to comply with

Komentarze do niniejszej Instrukcji

Brak uwag